![lyncole xit grounding lyncole xit grounding](http://northernpridecommunications.com/wp-content/uploads/2017/09/AUBURN-5-PROPANE-TANK.jpg)
This collective experience created the solution known as the VFC Facility Protection System. Provides greatest ability for protection against arcing faults. Lyncole has more than 120,000 XIT Grounding Systems in place. Will trip on first fault (it is this factor that occasionally leads to use of ungrounded circuits). Lyncole Grounding Solutions, LLC offers the XIT Grounding System, the originally patented XIT Rod ground resistance meters and monitors from AEMC and Megger.
![lyncole xit grounding lyncole xit grounding](https://vfclp.com/wp-content/uploads/2019/03/vfc_product_l_shaped_2.jpg)
The effort is at least a five-year program of monthly readings, to see how various grounding rod materials hold up in different soils and moisture levels. Fault current may need to be limited if equipment ratings are to be met. According to Williams, if grounding materials degrade, the quality of electrical power also may suffer, damaging sensitive electronic equipment or causing problems with its operation. Solidly grounded: Provides for the highest level of fault current to permit maximum ability for overcurrent protection for isolation of faulted circuit. Grounded for serving line-to-neutral loads: Z ? Z 1, where Z is the system fault impedance.Ī.
![lyncole xit grounding lyncole xit grounding](https://cdn.businessyab.com/assets/uploads/925c564c1c6cde5e63649a8aeb78007d_-united-states-california-los-angeles-county-torrance-voyager-street-3547-lyncole-xit-grounding-310-214-4000.jpg)
High-resistance grounded: The insertion of nearly the highest permissible resistance into the grounding connection R 0 ? X 0 c/3, where X 0 c is the capacitive zero-sequence reactance. Resistance grounded: Intentional insertion of resistance into the system grounding connection R 0 ?2 X 0. (Subscripts 1, 2, and 0 refer to positive-, negative-, and zero-sequence symmetrical components, respectively.) Harger Lightning & Grounding, pioneers in total systems integration, couples extraordinary service with high quality products. Solidly grounded: No intentional grounding impedance.Įffectively grounded: R 0 ? X 1, X 0 ?3 X 1, where R is the system fault resistance and X is the system fault reactance. Their Lyncole XIT Grounding Systems are warranted for 30 years and provide a high performance. The different levels of grounding impedance are: Lyncole XIT Grounding Systems have been demonstrated to work in soil conditions as diverse as Arctic permafrost and the Saudi Arabian desert sand. Lyncole is a grounding and electrical protection company.